Toroidal transformers
Types and features | Series index
Primary (V): 230 o 115 Secondary (V): Double: 2 x (4.5 / 6 / 7.5 / 9 / 12 / 15 / 18 / 24) |
||||||
---|---|---|---|---|---|---|
![]() |
T002
2x(6.0V...30.0V) 20.0 VA |
T003
2x(6.0V...30.0V) 30.0 VA |
T004
2x(6.0V...30.0V) 40.0 VA |
T005
2x(6.0V...30.0V) 50.0 VA |
T006
2x(6.0V...35.0V) 60.0 VA |
|
![]() |
T008
2x(6.0V...40.0V) 80.0 VA |
T012
2x(6.0V...40.0V) 120.0 VA |
T016
2x(10.0V...40.0V) 160.0 VA |
T020
2x(10.0V...40.0V) 200.0 VA |
T025
2x(12.0V...40.0V) 250.0 VA |
|
![]() |
T033
2x(15.0V...50.0V) 330.0 VA |
T050
2x(15.0V...55.0V) 500.0 VA |
T075
2x(24.0V...60.0V) 750.0 VA |
T100
2x(30.0V...80.0V) 1000.0 VA |
T150
2x(30.0V...80.0V) 1500.0 VA |
|
Custom transformer series | ||||||
![]() |
T200 Custom transformer serie 2000 VA |
T300 Custom transformer serie 3000 VA |
Technical specs | |
---|---|
Magnetic core | Magnetic core of grain-oriented silicon steel. |
Copper wire | Double isolation type |
Copper wire | Double isolation type |
Thermical class materials | B 130ºC/266ºF |
Dielectric strength pri/sec | 3,6 KV/1 min. |
Isolation: pri/sec | 5 MOhm a 500 Vcc |
Creepage lines and clearances | According regulation IEC/EN61558 |
Max. sec. power safety vaccum transformer | 50V (EN61558/6) 30V (UL1585/2) |
Ambient temperature | 40ºC/104ºF |
Winding identification | For colour references |